期刊論文1. | Munson, T. O.(1986)。Getting Started with Pyrolysis Capillary Gas Chromatography。Crime Laboratory Digest,13(13),82-91。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
2. | Bates, J. W.、Allinson, T.、Bal, T. S.(1989)。Capillary pyrolysis gas chromatography: A system employing a Curie point pyrolyser and a stationary phase of intermediate polarity for the analysis of paint resins and polymers。Forensic Science International,40(1),25-43。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
3. | Munson, T. O.(1989)。The Classification of Photocopies by Pyrolysis Gas Chromatography-Mass Spectrometry。Journal of Forensic Sciences,34(2),352-365。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
4. | Allen, T. J.、Schnetz, B.(1991)。The Removal of Paint Smears from Tools and Clothing for Microscopical Examination and Analysis。Forensic Science International,52(1),101-105。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
5. | Parybyk, A. E.、Kobus, H. J.(1990)。The Characterization of Plastic Automobile Bumper Bars Using Fourier Transform Infrared Spectroscopy (FTIR), Pyrolysis Gas Chromatography (PGC), and Energy Dispersive X-Ray Microanalysis Combined with a Scanning Electron Microscope (SEM-EDX)。Journal of Forensic Sciences,35(2),281-292。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
6. | Almer, J.(1991)。Subclassification of Polyacrylonitrile Fibres by Pyrolysis Capillary Gas Chromatography。Canadian Society of Forensic Science Journal,24(1),51-64。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
7. | (1988)。Cedar, cypress, or pine?。PEAK,1988(Summer),2。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
8. | Audette, R. J.、Percy, R. F. E.(1978)。A novel pyrolysis technique for micro paint analysis。J Forensic Sci,23,672。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
9. | Bakowski, N. L.、Bender, E. C.、Munson, T. O.(1985)。Comparison and identification of adhesives used in improvised explosive devices by pyrolysis-capillary column gas chromatography-mass spectrometry。Journal of Analytical and Applied Pyrolysis,8,483-492。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
10. | Blackledge, R. D.(1981)。Pyrolysis Gas Chromatography of Automobile Rubber Bumper Guard Samples。Journal of Forensic Sciences,26(3),557-559。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
11. | Burke, P.、Curry, C. J.、Davies, L. M.、Cousins, D. R.(1985)。A comparison of pyrolysis mass spectrometry, pyrolysis gas chromatography and infra-red spectroscopy for the analysis of paint resins。Forensic Science International,28(3/4),201-219。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
12. | Cassidy, F. H.(1979)。Chewing Gum Analysis by Pyrolysis Gas Chromatography。Tieline,5(4),59。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
13. | Challinor, J. M.(1989)。A pyrolysis-derivatisation-gas chromatography technique for the structural elucidation of some synthetic polymers。Journal of Analytical and Applied Pyrolysis,16(4),323-333。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
14. | Challinor, J. M.(1983)。Forensic applications of pyrolysis capillary gas chromatography。Forensic Science International,21(3),269-285。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
15. | Clausen, P. K.、Rowe, W. F.(1980)。Differentiation of fetal and adult bloodstains by pyrolysis-gas-liquid chromatography。J Forensic Sci,25(4),765-778。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
16. | Curry, C. J.(1937)。Pyrolysis-mass spectrometry studies of adhesives。Journal of Analytical and Applied Pyrolysis,11,213-225。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
17. | Davis, R. J.(1978)。Pyrolysis GC Analysis of Rubber。Tieline,5(1),24。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
18. | Ding, J. K.、Liu, H.-S.(1989)。A study of identification of trace rubber residues in marks from rubber-soled shoes and tyres by Py-GC。Forensic Science International,43(1),45-50。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
19. | Ericsson, I.(1985)。Influence of pyrolysis parameters on results in pyrolysis-gas chromatography。Journal of Analytical and Applied Pyrolysis,8,73-86。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
20. | Fischer, W. G.、Kusch, P.(1990)。Automatic sampler for curie-point pyrolysis-gas chromatography with on-column introduction of pyrolysates。Journal of Chromatography,518,9-19。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
21. | Fischer, W. G.、Kusch, P.(1990)。Automated system for Curie-point pyrolysis GC。Int Lab,20,52。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
22. | Freed, D. J.、Liebman, S. A.(1985)。Basic analytical pyrolysis instrumentation。Chromatogr Sci,28,15。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
23. | Fukuda, K.(1985)。The pyrolysis gas chromatographic examination of Japanese car paint flakes。Forensic Science International,29(3/4),227-236。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
24. | Hardin, I. R.、Wang, X. Q.(1989)。The use of pyrolysis-gas chromatography in textiles as an identification method。Textile Chem Colorist,21,29。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
25. | Heylin, M.(19910923)。Sabotage refuted as cause of battleship explosion。C&EN,14。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
26. | Hu, J. C.(1977)。Pyrolysis gas chromatography analysis of rubbers and other high polymers。Anal Chem,49,537。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
27. | Ishizawa, F.、Misawa, S.(1990)。Capillary column pyrolysis-gas chromatography of hair: A short study in personal identification。Journal of the Forensic Science Society,30(4),201-209。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
28. | Keto, R. O.(1989)。Comparison of smokeless powders by pyrolysis capillary gas chromatography and pattern recognition。J Forensic Sci,34,74。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
29. | Lennard, C. J.、Margot, P. A.(1989)。Analysis of synthetic shoe soles by FTIR microspectromety and pyrolysis GC: a case Study。J Forensic Ident,39,239。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
30. | Lennard, C. J.、Mazella, W. D.(1991)。A simple combined technique for the analysis of toners and adhesives。J Forensic Sci Soc,31,365。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
31. | Levy, E. J.、Walker, J. Q.(1984)。The modern molecular thermometer, a standardization method for pyrolysis gas chromatography。J Chromatogr Sci,22,49。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
32. | Levy, E. J.、Wampler, T. P.(1986)。Applications of pyrolysis gas chromatography/mass spectrometry to toner materials from photocopiers。Journal of Forensic Sciences,31,258-271。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
33. | Levy, E. J.、Wampler, T. P.(1986)。Identification and differentiation of synthetic polymers by pyrolysis capillary gas chromatography。Journal of Chemical Education,63,A64。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
34. | Liebman, S. A.、Levy, E. J.(1985)。Pyrolysis and GC in polymer analysis。Chromatogr Sci,29,1。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
35. | Liebman, S. A.、Wampler, T. P.、Levy, E. J.(1984)。Developments in pyrolysis capillary GC。J High Res Chromatogr Chromatogr Commun,7,172。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
36. | Munson, T. O.(1989)。A simple method for sampling photocopy toners for examination by pyrolysis gas chromatography。Crime Lab Digest,16,6。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
37. | Munson, T. O.(1987)。A survey of the use of analytical pyrolysis by forensic laboratories in the United States。Crime Lab Digest,14,112。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
38. | Munson, T. O.(1987)。The status of hair comparison by pyrolysis gas chromatography。Crime Lab Digest,14,153。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
39. | Nishikawa, M.、Tatsuno, M.、Suzuki, S.、Tsuchihashi, H.(1991)。Analysis of methylbenactyzium bromide in human urine by thin-iayer chromatography and pyrolysis gas chromatography。Forensic Sci Int,49,197。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
40. | Northrop, D. M.、Rowe, W. F.(1986)。Effect of the Soil Environment on the Biodeterioration of Man-Made Textiles。Biodeterioration Res,1,7。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
41. | Nowicki, J.、Vanderwerff, K.(1987)。Examination of U.S. automotive paints. II. Discrimination of topcoats by chemical and instrumental techniques。MAFS News,16,1。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
42. | Reddmann, C.、Kurz, H.(1985)。Pyrolysis-capillary GC-FTIR coupling: Its application to technologically important elastomers in automobile construction。LaborPraxis,9,454。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
43. | Riska, G. D.、Estes, S. A.、Beyer, J. O.、Uden, P. C.(1983)。Plasma emission spectral detection for pyrolysis-gas chromatography。Spectrochimica Acta,38B,407。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
44. | Saferstein, R.、Ostberg, E. C.(1988)。Dual column pyrolysis gas chromatography。Crime Lab Digest,15,39。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
45. | Saǧlam, M.(1986)。Qualitative and quantitative analysis of methyl acrylate or methyl methacrylate of acrylonitrile fibers by pyrolysis gas chromatography。Journal of Applied Polymer Science,32(7),5719-5726。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
46. | Schulten, H.-R.、Fischer, W.、Wallstab, H. J.(1987)。New automatic sampler for Curie-Point pyrolysis its combination with gas chromatography。Journal of high resolution chromatography & chromatography communications,10(8),467-469。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
47. | Totty, R. N.(1990)。Analysis and Differentiation of Photocopy Toners。Forensic Science Review,2(1),1-23。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
48. | Tsuge, S.、Ohiani, H.、Matsubara, H.、Ohsawa, M.(1987)。Some empirical considerations on the pyrolysis-gas chromatographic conditions required to obtain characteristic and reliable high-resolution pyrograms for polymer samples。Journal of Analytical and Applied Pyrolysis,11,181-194。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
49. | Tsuge, S.、Takeuchi, T.(1977)。Vertical Furnace-Type Sampling Device for Pyrolysis Gas Chromatography。Anal Chem,49,348。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
50. | Walker, J. Q.(1977)。Pyrolysis Gas Chromatographic Correlation Trials of the American Society for Testing and Materials。Journal of Chromatographic Science,15(7),267-274。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
51. | Wampler, T. P.(1989)。A selected bibliography of and analytical pyrolysis applications 1980-1989。J Anal Appl Pyrol,16,291。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
52. | Wampler, T. P.、Bowe, W. A.、Higgins, J.、Levy, E. J.(1985)。Systems approach to automatic cryofocusing in purge and trap, headspace, and pyrolytic analysis。Am Lab,17(8),82。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
53. | Wampler, T. P.、Levy, E. J.(1985)。Cryogenic focusing of pyrolysis products for direct (splitless) capillary gas chromatography。Journal of Analytical and Applied Pyrolysis,8,65-71。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
54. | Wampler, T. P.、Levy, E. J.(1987)。Reproducibility in pyrolysis: recent developments。Journal of Analytical and Applied Pyrolysis,12,75-82。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
55. | Washall, J. W.、Wampler, T. P.(1991)。Direct-pyrolysis Fourier transform-infrared spectroscopy for polymer analysis。Spectroscopy,6,38。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
56. | Wheals, B. B.(1981)。Review--analytical pyrolysis techniques in forensic science。J Anal Appl Pyrol,2,277。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
57. | Whiton, R. S.、Morgan, S. L.(1985)。Modified interface for pyrolysis gas chromatography with capillary columns。Anal Chem,57,778。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
58. | Williams, E.、Munson, T.(1988)。The Comparison of Black Polyvinylchloride (PVC) Tapes by Pyrolysis Gas Chromatography。Journal of Forensic Sciences,33(5),1163-1170。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
59. | Wright, D. W.、Mahler, K. O.、Ballard, L. B.、Dawes, E.(1986)。The application of multidimensional techniques to the rapid pyrolysis-GC profiling of synthetic polymers。J Chromatogr Sci,24,13。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
60. | Wright, M. M.、Wheals, B. B.(1987)。Pyrolysis-mass spectrometry of natural gums, resins, and waxes and its use for detecting such materials in ancient Egyptian mummy cases (cartonnages)。Journal of Analytical and Applied Pyrolysis,11,195-211。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |
61. | Zimmerman, J.、Mooney, D.、Kimmett, M. J.(1986)。Preliminary Examination of Machine Copier Toners by Infrared Spectrophotometry and Pyrolysis Gas Chromatography。Journal of Forensic Sciences,31(2),489-493。 ![](/gs32/thssjcncl/image/nclsfx.gif) ![new window](/gs32/images/newin.png) |