題名:臺灣氣候下室內調濕建材之適用性探討
書刊名:建築學報
作者:蔡耀賢 引用關係江哲銘
作者(外文):Tsay, Y. S.Chiang, C. M.
出版日期:2009
卷期:69
頁次:頁35-50
主題關鍵詞:室內空氣品質數值解析調濕效果熱與濕氣同時移動Indoor air qualityNumerical simulationMoisture buffering effectHeat and vapor transport
原始連結:連回原系統網址new window
相關次數:
  • 被引用次數被引用次數:期刊(4) 博士論文(1) 專書(0) 專書論文(0)
  • 排除自我引用排除自我引用:3
  • 共同引用共同引用:3
  • 點閱點閱:28
期刊論文
1.Andrade, C.、Sarria, J.、Alonso, C.(1999)。Relative humidity in the interior of concrete exposed to natural and artificial weathering。Cement and Concrete Research,29(8),1249-1259。  new window
2.Künzel, H. M.、Holm, A.、Zirkelbach, D.、Karagiozis, A. N.(2005)。Simulation of indoor temperature and humidity conditions including hygrotherrmal interactions with building envelope。Solar Energy,78(4),554-561。  new window
3.吳佩芝、蘇慧貞、Lin, Chia-Yin(2000)。Characteristics of indoor and outdoor airborne fungi at suburban and urban homes in two seasons。The Science of the Total Environmental 2000,253(1-3),111-118。  new window
4.Bomehag, C. G.、Sundell, J.、Bonini, S.、Custovic, A.、Malmberg, P.、SkerfVing, S.、Sigsgaard, T.、Verhoeff, A.(2004)。Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effects。Indoor Air,14(4),243-257。  new window
5.林憲德、黃國倉(2005)。臺灣TMY2標準氣象年之研究與應用。建築學報,53,79-94。new window  延伸查詢new window
6.Abe, K.、Nagao, Y.、Nakada, T.、Sakuma, S.(1996)。Assessment of Indoor Climate in an Apartment by Use of a Fungal Index。Applied and Environmental Microbiology,62(3),959-963。  new window
7.Burch, D. M.、Thomas, W. C.、Fanney, A. H.(1992)。Water Vapor Permeability Measurements of Common Building Materials。ASHRAE Transactions,98(2),486-494。  new window
8.Clarkea, J. A.、Johnstonea, C. M.、Kellya, N. J.、McLeana, R. C.、Andersonb, J. A.、Rowanb, N. J.、Smithb, J. E.(1999)。A Technique for the Prediction of the Conditions Leading to Mould Growth in Buildings。Building and Environment,34,515-512。  new window
9.Fischera, G.、Müllera, T.、Schwalbea, R.、Ostrowskia, R.、Dott, W.(2000)。Exposure to Airborne Fungi, MVOC and Mycotoxins in Biowaste-handling Facilities。International Journal of Hygiene and Environmental Health,203(2),97-104。  new window
10.Hameury, S.(2005)。Moisture Buffering Capacity of Heavy Timber Structures Directly Exposed to an Indoor Climate: A Numerical Study。Building and Environment,40(10),1400-1412。  new window
11.Harper, G. J.(1961)。Airborne Micro-organisms: Survival Tests with Four Viruses。The Journal of Hygiene,59(4),479-486。  new window
12.Leino, M.、Makelaw, M.、Reijulaz, K.、Haahtelaw, T.、Mussalo-Rauhamaaw, H.、Tuomiz, T.、Hintikkaz, E.-L.、Alenius, H.(2003)。Intranasal Exposure to a Damp Building Mould, Stachybotrys Chartarum, Induces Lung Inflammation in Mice by Satratoxin-independent Mechanisms。Clinical Experimental Allergy,33,1603-1610。  new window
13.Matsumoto, M.、Tanaka, Y.(1990)。A Numerical Analysis of Moisture Behavior in a Porous Wall by Quasilinearized Equations。Energy and Buildings,15-16,861-874。  new window
14.Osanyintola, O. F.(2006)。Effect of Initial Conditions, Boundary Conditions and Thickness on the Moisture Buffering Capacity of Spruce Plywood。Energy and Buildings,38,1283-1292。  new window
15.Osanyintola, O. F.、Simonson, C. J.(2006)。Moisture Buffering Capacity of Hygroscopic Building Materials: Experimental Facilities and Energy Impact。Energy and Buildings,38(10),1270-1282。  new window
16.Philip, J. R.、De Vries, D. A.(1957)。Moisture Movement in Porous Materials under Temperature Gradients。Transactions American Geophysical Union,38,222-232。  new window
17.Richards, R. F.、Burch, D. M.、Thomas, W. C.(1992)。Water Vapor Sorption Measurements of Common Building Materials。ASHRAE Transactions,98(2)。  new window
18.Rode, C.(2004)。Evaluation of Moisture Buffer Effects by Performing Whole-building Simulation。ASHRAE Transactions,110(2),783-794。  new window
19.Wessén, B.、Schoeps, K.-O.(1996)。Microbial Volatile Organic Compounds - What Substances Can Be Found in Sick Buildings?。The Analyst,121(9),1203-1205。  new window
20.吉田治典、寺井俊夫、末吉弘明(1991)。多層壁の熱.水分同時移動における三角波応答の離散フーリエ変換による計算法。空気調和衛生工学会論文集,46,21-30。  延伸查詢new window
21.安宅勇二、加藤信介、朱清宇(2005)。水銀圧入法による各種建築材料.吸着剤の有効拡散係数の算出。日本建築学会環境系論文集,589,15-21。  延伸查詢new window
22.安宅勇二、加藤信介、徐長厚、朱清宇、長谷川あゆみ(2005)。各種建築材料および吸着材の水蒸気およびホルムアルデヒド吸着等温線の測定。日本建築学会環境系論文集,595,49-56。  延伸查詢new window
23.柳宇、池田耕一(2007)。空調システムにおける微生物汚染の実態と対策に関する研究:第1 報 微生物の生育環境と汚染実態。日本建築学会環境系論文集,593,49-56。  延伸查詢new window
研究報告
1.Hansen, K. K.(1972)。Sorption Isotherms - A Catalogue。  new window
學位論文
1.紀碧芳(2003)。受黴菌污染建材上之黴菌種類研究(碩士論文)。國立成功大學。  延伸查詢new window
圖書
1.Barenbrug, A. W. T.(1974)。Psychrometry and Psychrometric Charts。Psychrometry and Psychrometric Charts。Cape Town, South Africa。  new window
2.日本工業規格(2002)。JIS A1470-1: 調湿建材の吸放湿性試験方法-第1部:湿度応答法。JIS A1470-1: 調湿建材の吸放湿性試験方法-第1部:湿度応答法。日本,東京。  延伸查詢new window
3.日本工業規格(2002)。JIS A1470-2: 調湿建材の吸放湿性試験方法-第2部:密閉箱法。JIS A1470-2: 調湿建材の吸放湿性試験方法-第2部:密閉箱法。日本,東京。  延伸查詢new window
4.日本工業規格(1995)。JIS A1324: 建築材料の透湿性測定方法。JIS A1324: 建築材料の透湿性測定方法。日本,東京。  延伸查詢new window
5.(2001)。化学工学便覧 改訂六版。化学工学便覧 改訂六版。日本,東京。  延伸查詢new window
6.池田耕一(2005)。シックハウスに関する海外の法規制など。シックハウスを防ぐ最新知識。日本,東京。  延伸查詢new window
7.新建築学大系編集委員会(1984)。新建築学大系10-環境物理。新建築学大系10-環境物理。日本,東京。  延伸查詢new window
 
 
 
 
第一頁 上一頁 下一頁 最後一頁 top