詳目顯示

回上一頁
題名:臺灣建築帷幕牆材料應用對節能效率之研究
書刊名:明道學術論壇
作者:張源修侯文祥
作者(外文):Chang, Yuan-hsiouHou, Wen-shang
出版日期:2011
卷期:7:2
頁次:頁65-89
主題關鍵詞:惟幕牆辦公大樓熱傳熱阻空間耗能Curtain wallOffice buildingsHeat transferThermal resistanceSpace energy consumption
原始連結:連回原系統網址new window
相關次數:
  • 被引用次數被引用次數:期刊(1) 博士論文(0) 專書(0) 專書論文(0)
  • 排除自我引用排除自我引用:1
  • 共同引用共同引用:0
  • 點閱點閱:42
帷幕牆是近代建築產物,由於外觀具科技感、施工便利與低成本因素深受歡迎。但帷幕牆適用於寒帶國家,藉由玻璃溫室蓄熱原理,提升室內溫度達到舒適性,並降低暖氣之用電量。而帷幕牆傳至亞熱帶的台灣,卻造成反效果,成為大樓耗電量的主因,因此,如何保有帷幕牆之優點又能達到節能效益則是重要的課題之一。本研究選擇台北市地區同時興建之兩棟辦公大樓,所使用之帷幕牆框材分別為塑鋼與鋁,分別實測其透熱率與節能效益。結果得知塑鋼材質帷幕牆透熱率為87%~110%,鋁製帷幕牆透熱率為101%~174%從節能效益考量,兩者相較,使用塑鋼材質帷幕牆較鋁製帷幕牆每月可節省19%之電費。
Curtain wall is a product of modern architecture, as the appearance of a technological sense, convenience and low cost factors of construction is more popular for people. Curtain wall suit for the cold area, through the glass greenhouse regenerative principle, improve the indoor temperature to comfort and reduce heating and electricity. The curtain wall spread to subtropical Taiwan, but have adverse effect, as the main cause of building energy consumption, therefore, how to retain the advantages of curtain wall and reach the energy efficiency is one of important topics. In this study, two sites of office buildings in Taipei are selected as research target. We aim to measure the energy consumption of the polyoxymethylene (POM) curtain wall and the aluminum curtain wall. Due to the high proportion area are composed by glass, the thermal resistance is limited in window frame materials. The POM curtain wall has heat penetration rate of 87% to 110% and the aluminum curtain wall has heat penetration rate was 101% ~ 174% and its indoor temperature is higher than outdoor. By calculating the unit space of energy consumption, Estimating the expenditure of electricity consumption in regulating indoor thermal condition, aluminum curtain wall building is more than POM curtain wall building can save about 19% of the expenditure of electricity consumption per month.
期刊論文
1.劉憲宗(2003)。建築師雜誌44-53。  延伸查詢new window
2.Larsson, U.、Moshfegh, B.、Sandberg, M.(1999)。Thermal analysis of super insulated windows numerical and experimental investigations。Energy and Buildings,29,121-128。  new window
3.Larsson, U.、Moshfegh, B.(2002)。Experimental investigation of downdraught from well-insulated windows。Building and Environment,37,1037-1082。  new window
4.Peter, R. L.、Arasteh, D.、Huizengan, C.(2000)。Window Performance for Human Thermal Comfort。ASHRAE,594- 602。  new window
5.Saso, M.、Novak, P.(1998)。Heat transfer through a double pane window with an insulation screen open at the top。Energy and Buildings,28,257-268。  new window
6.Alvarez, G.、Palacios, M. J.、Flores, J. J.(2000)。A test method to evaluate the thermal performance of window glazings。Applied Thermal Engineering,20,803-812。  new window
7.Arasteh, D . K.、Reilly, M. S.、Rubin, M. D.(1989)。A Versatile Procedure for Calculating Heat Transfer through Windows。ASHRAE,755-765。  new window
8.Petter, W.(2001)。Convective heat transfer coefficients in a full-scale room with and without furniture。Building and Environment,36,743-751。  new window
會議論文
1.張世典、蔡必超、楊謙柔(2003)。辦公大樓節能調查評析。建築物能源管理技術研討會。台北:經濟部能源委員會。  延伸查詢new window
研究報告
1.谷家恆、楊冠雄(2000)。建築外殼耗能管制實施現況檢討研究。  延伸查詢new window
2.黃瑞隆、楊冠雄(2000)。玻璃帷幕牆對建築空調耗能影響之研究。  延伸查詢new window
3.顏貽乙、簡國祥(2001)。建築外殼性能檢測(ニ)--玻璃日光輻射熱取得率量測實驗室建置與建築外殼建材隔熱性能資建立。  延伸查詢new window
學位論文
1.顧孝偉(2003)。住宅電量監測與解析之研究(碩士論文)。國立成功大學。  延伸查詢new window
圖書
1.陳啟中(2000)。建築物理概論。詹氏書局。  延伸查詢new window
2.林憲德(1997)。建築空調節能設計--空調系統耗能係數PACS。詹氏書局。  延伸查詢new window
3.林憲德、賴榮平、周家鵬(1991)。建築節約能源設計手冊。台北:内政部建築研究所籌備處。  延伸查詢new window
 
 
 
 
第一頁 上一頁 下一頁 最後一頁 top
:::
無相關博士論文
 
無相關書籍
 
無相關著作
 
無相關點閱
 
QR Code
QRCODE